{"id":9590,"date":"2023-04-28T14:31:08","date_gmt":"2023-04-28T12:31:08","guid":{"rendered":"https:\/\/www.tec4med.com\/?post_type=landingpages&#038;p=9590"},"modified":"2023-04-28T15:11:26","modified_gmt":"2023-04-28T13:11:26","slug":"anforderungen-an-trockeneis-und-fluessigstickstoff","status":"publish","type":"landingpages","link":"https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/","title":{"rendered":"Anforderungen an Trockeneis und Fl\u00fcssigstickstoff (LN2) f\u00fcr Kryolagerung und -versand"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][dhsv_vc_stage_case button=&#8221;url:%23contact|title:Free%20Consultation&#8221; image=&#8221;899&#8243; product_image=&#8221;9126&#8243;]<\/p>\n<h1><span style=\"color: #000000;\">Anforderungen an<\/span> <span style=\"color: #5eb676;\">Trockeneis und Fl\u00fcssigstickstoff (LN2)<\/span> <span style=\"color: #000000;\">f\u00fcr Kryolagerung und -versand<\/span><\/h1>\n<hr \/>\n<p><span style=\"color: #000000;\">Sowohl Trockeneis als auch Fl\u00fcssigstickstoff (LN2) werden in der Regel als K\u00fchlmittel f\u00fcr den Tiefk\u00fchlversand von Arzneimitteln und anderen temperaturempfindlichen Produkten verwendet. Die Entscheidung zwischen der Verwendung von Trockeneis und LN2 h\u00e4ngt von mehreren Faktoren ab, darunter das zu versendende Produkt, der gew\u00fcnschte Temperaturbereich und die Dauer des Transports. Der Transport oder die Lagerung von Tiefk\u00fchlprodukten birgt aufgrund der Beschaffenheit der beteiligten Gase (Kohlendioxid und Stickstoff) und ihrer extremen K\u00e4lte verschiedene Sicherheitsrisiken in sich.<\/span>[\/dhsv_vc_stage_case][vc_empty_space height=&#8221;140px&#8221; mobile_height=&#8221;32px&#8221; tablet_height=&#8221;140px&#8221;][\/vc_column][\/vc_row][vc_section][vc_row][vc_column width=&#8221;1\/2&#8243;][dhsv_vc_anker type=&#8221;point&#8221; title=&#8221;Sicherheit&#8221; id=&#8221;_sicherheit&#8221;][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<h2>Minimieren Sie die Sicherheitsrisiken bei der Lagerung oder dem Transport von Kryogenen Produkten<\/h2>\n<p>Es gibt zwei wichtige Faktoren, die bei der Bef\u00f6rderung und Lagerung von Kryogenen zu beachten sind:<\/p>\n<ul>\n<li><strong>Sicherheit:<\/strong> Der sichere Umgang mit kryogenen Stoffen ist von entscheidender Bedeutung und muss strengen beh\u00f6rdlichen Anforderungen gen\u00fcgen. Bei unsachgem\u00e4\u00dfer Handhabung k\u00f6nnen Trockeneis und LN2 Gesundheitsgefahren wie Erfrierungen und Erstickungen verursachen.<\/li>\n<li><strong>Spezialisierte Ausr\u00fcstung:<\/strong> Elektronische Bauteile vertragen K\u00e4lte im Allgemeinen nicht gut. Es muss sichergestellt werden, dass Ihre \u00dcberwachungsger\u00e4te, wie z. B. Datenlogger, beim Umgang mit kryogenen Sendungen ordnungsgem\u00e4\u00df funktionieren.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;897&#8243; img_size=&#8221;full&#8221;][\/vc_column][\/vc_row][\/vc_section][vc_section][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_empty_space height=&#8221;120px&#8221;][vc_single_image image=&#8221;925&#8243; img_size=&#8221;full&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h3>Temperaturbereich<\/h3>\n<ul>\n<li>Trockeneis kann Temperaturen zwischen -60\u00b0C und -80\u00b0C halten. Die durchschnittliche Sublimationstemperatur liegt bei -78 \u00b0C, aber je nach Faktoren wie Vibration, Luftdruck und Verschmutzung des Trockeneises k\u00f6nnen die Temperaturen auch viel niedriger liegen.<\/li>\n<li>LN2 kann Temperaturen von bis zu -196\u00b0C halten. Wenn das Produkt bei extrem niedrigen Temperaturen aufbewahrt werden muss, ist LN2 m\u00f6glicherweise die bessere Wahl.<\/li>\n<\/ul>\n<h3>Dauer der Lieferung<\/h3>\n<ul>\n<li>Trockeneis hat im Vergleich zu LN2 eine k\u00fcrzere Lebensdauer und h\u00e4lt in der Regel zwischen 24 und 48 Stunden.<\/li>\n<li>LN2 kann bis zu mehreren Wochen halten. Wenn die Sendung eine l\u00e4ngere Transportzeit erfordert, ist LN2 m\u00f6glicherweise die bessere Wahl.<\/li>\n<\/ul>\n<h3>Sicherheitsaspekte<\/h3>\n<ul>\n<li>Trockeneis gilt im Allgemeinen als weniger gef\u00e4hrlich und ist einfacher zu handhaben, so dass es f\u00fcr manche Anwendungen die bessere Wahl ist.<\/li>\n<li>Die Handhabung und der Transport von LN2 erfordert aufgrund der Risiken, die mit den extrem niedrigen Temperaturen verbunden sind, eine spezielle Ausbildung und Ausr\u00fcstung.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][\/vc_section][vc_section][vc_row][vc_column][vc_empty_space height=&#8221;120px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][dhsv_vc_anker type=&#8221;point&#8221; title=&#8221;Ber\u00fccksichtigung&#8221; id=&#8221;_ber\u00fccksichtigung&#8221;][vc_column_text]<\/p>\n<h2>Was ist bei der Verwendung von Echtzeit-\u00dcberwachungsger\u00e4ten f\u00fcr Trockeneis oder LN2 zu beachten?<\/h2>\n<p>Extreme K\u00e4lte kann die Leistung elektronischer Komponenten und Schaltkreise beeintr\u00e4chtigen, indem sie zu Fehlfunktionen, verminderter Leistung oder zu Sch\u00e4den oder Ausf\u00e4llen f\u00fchrt. Aus diesem Grund m\u00fcssen Datenlogger f\u00fcr den Transport und die Lagerung von Kryoprodukten in der Lage sein, Tiefk\u00fchlbedingungen und extremen Temperaturunterschieden standzuhalten.<\/p>\n<p>Elektronische Ger\u00e4te, die f\u00fcr den Einsatz bei extremen Temperaturen konzipiert sind, verf\u00fcgen oft \u00fcber besondere Merkmale wie isolierte Batterien, W\u00e4rmemanagementsysteme und feuchtigkeitsresistente Beschichtungen. Die speziell entwickelten drahtlosen Datenlogger von Tec4med k\u00f6nnen beispielsweise Temperaturen von -200 \u00b0C und einer Luftfeuchtigkeit von 100 % r.H. standhalten und sind gem\u00e4\u00df den hohen Standards der ISO17025 vorkalibriert.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;9212&#8243; img_size=&#8221;full&#8221;][\/vc_column][\/vc_row][\/vc_section][vc_section][vc_row][vc_column][dhsv_vc_anker type=&#8221;point&#8221; title=&#8221;Anforderungen&#8221; id=&#8221;_anforderungen&#8221;][vc_empty_space height=&#8221;64px&#8221;][vc_column_text]<\/p>\n<h2 style=\"text-align: center;\">Einhaltung gesetzlicher Vorschriften und Anforderungen<\/h2>\n<p style=\"text-align: center;\">Die US Food and Drug Administration (FDA), die Occupational Safety and Health Administration (OSHA) und das Department of Transportation (DOT) legen die gesetzlichen Anforderungen f\u00fcr den Umgang mit kryogenem Transport fest. Die Vorschriften f\u00fcr die Verwendung von Trockeneis und LN2 h\u00e4ngen von der jeweiligen Anwendung und dem zu transportierenden Produkt ab.<\/p>\n<p style=\"text-align: center;\">Durch die richtige Auswahl von Datenloggern und \u00dcberwachungsger\u00e4ten k\u00f6nnen Sie sicherstellen, dass Ihre kryogenen Lager- und Versandprozesse ordnungsgem\u00e4\u00df \u00fcberwacht werden und den gesetzlichen Anforderungen entsprechen.<\/p>\n<p>[\/vc_column_text][vc_empty_space][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h3>Trockeneis<\/h3>\n<ul>\n<li>Gem\u00e4\u00df den DOT-Vorschriften m\u00fcssen Packst\u00fccke, die Trockeneis enthalten, mit dem Aufkleber &#8220;Dry Ice&#8221; oder &#8220;Carbon Dioxide, Solid&#8221; gekennzeichnet sein.<\/li>\n<li>Die Menge an Trockeneis, die transportiert werden darf, ist begrenzt (normalerweise 5,5 Pfund pro Packst\u00fcck oder 440 Pfund pro Fahrzeug).<\/li>\n<li>Packst\u00fccke, die Trockeneis enthalten, m\u00fcssen ausreichend bel\u00fcftet werden, um die Bildung von Kohlendioxidgas zu verhindern.<\/li>\n<li>Alle Packst\u00fccke, die Trockeneis enthalten, m\u00fcssen ordnungsgem\u00e4\u00df gekennzeichnet und etikettiert sein, um eine ordnungsgem\u00e4\u00dfe Handhabung w\u00e4hrend des Transports zu gew\u00e4hrleisten.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h3>Fl\u00fcssiger Stickstoff<\/h3>\n<ul>\n<li>Der Transport von LN2 erfordert den Einsatz spezieller Ausr\u00fcstung, einschlie\u00dflich kryogener Lagertanks, kryogener Beh\u00e4lter und vakuumisolierter Rohre.<\/li>\n<li>Fl\u00fcssigstickstofftanks m\u00fcssen in einem bel\u00fcfteten Beh\u00e4lter transportiert werden, um einen Druckaufbau zu verhindern und sicherzustellen, dass sich kein gef\u00e4hrliches Volumen in der Umgebungsluft ansammelt.<\/li>\n<li>Das mit dem Transport von LN2 befasste Personal muss in der sicheren Handhabung von kryogenen Stoffen geschult sein.<\/li>\n<li>Alle Beh\u00e4lter, die LN2 enthalten, m\u00fcssen ordnungsgem\u00e4\u00df mit dem Etikett &#8220;Cryogenic Liquid&#8221; und dem Produktnamen gekennzeichnet sein.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][\/vc_section][vc_row][vc_column][vc_empty_space height=&#8221;120px&#8221;][\/vc_column][\/vc_row][vc_section][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_empty_space height=&#8221;64px&#8221;][dhsv_vc_anker type=&#8221;point&#8221; title=&#8221;Vorteile&#8221; id=&#8221;_vorteile&#8221;][vc_column_text]<\/p>\n<h2>Der Tec4med-Vorteil<\/h2>\n<p>Tec4meds L\u00f6sungen f\u00fcr die Verfolgung und \u00dcberwachung kryogener Daten bieten eine umfassende L\u00f6sung f\u00fcr den Vertrieb von Trockeneis und LN2, einschlie\u00dflich wiederverwendbarer Kryobeh\u00e4lter und Transportbeh\u00e4lter, Sensoren und Ger\u00e4te f\u00fcr die Datenaufzeichnung sowie Cloud-basierte Software f\u00fcr die \u00dcberwachung und Einhaltung von Temperaturbereichen. Sie bieten eine vollst\u00e4ndige Transparenz der Lieferkette und automatisieren die Auswertungsprozesse, um manuelle Fehler oder Ungenauigkeiten zu vermeiden und so ein optimales Audit Trail- und Compliance-Management zu gew\u00e4hrleisten.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;9126&#8243; img_size=&#8221;full&#8221;][\/vc_column][\/vc_row][\/vc_section][vc_section][vc_row][vc_column][dhsv_vc_product_features main_title=&#8221;Vorteile&#8221; image=&#8221;8811&#8243; right_title=&#8221;Vorteile&#8221; features=&#8221;%5B%7B%22list%22%3A%22%255B%257B%257D%255D%22%7D%5D&#8221; facts=&#8221;%5B%7B%22title%22%3A%22%20%22%2C%22list%22%3A%22%255B%257B%2522fact%2522%253A%2522Konform%2520nach%2522%252C%2522value%2522%253A%2522GDP%252C%2520GMP%252C%2520GAMP5%252C%2520ISO17025%252C%2520FDA%252021%2520CFR%2520Part%252011%2522%257D%252C%257B%2522fact%2522%253A%2522Voll%2520IATA-konform%2522%252C%2522value%2522%253A%2522und%2520kann%2520ohne%2520weitere%2520Ausnahmen%2520in%2520Flugzeugen%2520verwendet%2520werden%2522%257D%252C%257B%2522fact%2522%253A%2522Weltweite%2522%252C%2522value%2522%253A%2522Datenaufzeichnung%2520mit%2520einfacher%2520In-App-Analyse%2520aller%2520Sensordaten%2522%257D%252C%257B%2522fact%2522%253A%2522Risiko%2520und%2520Kosten%2522%252C%2522value%2522%253A%2522Reduzierung%2520durch%2520effizientere%2520und%2520sichere%2520Arbeitsabl%25C3%25A4ufe%2522%257D%255D%22%7D%5D&#8221;][\/dhsv_vc_product_features][\/vc_column][\/vc_row][\/vc_section]<\/p>\n<\/div>","protected":false},"featured_media":3298,"template":"","class_list":["post-9590","landingpages","type-landingpages","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Anforderungen an Trockeneis und Fl\u00fcssigstickstoff<\/title>\n<meta name=\"description\" content=\"Minimieren Sie die Sicherheitsrisiken bei der Lagerung oder dem Transport von Kryogenen Stoffen, Chemikalien &amp; Pharmazeutika\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Anforderungen an Trockeneis und Fl\u00fcssigstickstoff\" \/>\n<meta property=\"og:description\" content=\"Minimieren Sie die Sicherheitsrisiken bei der Lagerung oder dem Transport von Kryogenen Stoffen, Chemikalien &amp; Pharmazeutika\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/\" \/>\n<meta property=\"og:site_name\" content=\"Tec4med Lifescience GmbH\" \/>\n<meta property=\"article:modified_time\" content=\"2023-04-28T13:11:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tec4med.com\/wp-content\/uploads\/tec4med-target-group-business-woman-03-1-1600x1067.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1600\" \/>\n\t<meta property=\"og:image:height\" content=\"1067\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"4\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tec4med.com\\\/de\\\/anforderungen-an-trockeneis-und-fluessigstickstoff\\\/\",\"url\":\"https:\\\/\\\/www.tec4med.com\\\/de\\\/anforderungen-an-trockeneis-und-fluessigstickstoff\\\/\",\"name\":\"Anforderungen an Trockeneis und Fl\u00fcssigstickstoff\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tec4med.com\\\/de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tec4med.com\\\/de\\\/anforderungen-an-trockeneis-und-fluessigstickstoff\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tec4med.com\\\/de\\\/anforderungen-an-trockeneis-und-fluessigstickstoff\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tec4med.com\\\/wp-content\\\/uploads\\\/tec4med-target-group-business-woman-03-1.jpg\",\"datePublished\":\"2023-04-28T12:31:08+00:00\",\"dateModified\":\"2023-04-28T13:11:26+00:00\",\"description\":\"Minimieren Sie die Sicherheitsrisiken bei der Lagerung oder dem Transport von Kryogenen Stoffen, Chemikalien & Pharmazeutika\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tec4med.com\\\/de\\\/anforderungen-an-trockeneis-und-fluessigstickstoff\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tec4med.com\\\/de\\\/anforderungen-an-trockeneis-und-fluessigstickstoff\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.tec4med.com\\\/de\\\/anforderungen-an-trockeneis-und-fluessigstickstoff\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.tec4med.com\\\/wp-content\\\/uploads\\\/tec4med-target-group-business-woman-03-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.tec4med.com\\\/wp-content\\\/uploads\\\/tec4med-target-group-business-woman-03-1.jpg\",\"width\":5760,\"height\":3840,\"caption\":\"Mature woman showing something to male colleague on printing machine. Workers looking at printing press and discussing.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tec4med.com\\\/de\\\/anforderungen-an-trockeneis-und-fluessigstickstoff\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tec4med.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Anforderungen an Trockeneis und Fl\u00fcssigstickstoff (LN2) f\u00fcr Kryolagerung und -versand\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tec4med.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.tec4med.com\\\/de\\\/\",\"name\":\"Tec4med Lifescience GmbH\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tec4med.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Anforderungen an Trockeneis und Fl\u00fcssigstickstoff","description":"Minimieren Sie die Sicherheitsrisiken bei der Lagerung oder dem Transport von Kryogenen Stoffen, Chemikalien & Pharmazeutika","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/","og_locale":"de_DE","og_type":"article","og_title":"Anforderungen an Trockeneis und Fl\u00fcssigstickstoff","og_description":"Minimieren Sie die Sicherheitsrisiken bei der Lagerung oder dem Transport von Kryogenen Stoffen, Chemikalien & Pharmazeutika","og_url":"https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/","og_site_name":"Tec4med Lifescience GmbH","article_modified_time":"2023-04-28T13:11:26+00:00","og_image":[{"width":1600,"height":1067,"url":"https:\/\/www.tec4med.com\/wp-content\/uploads\/tec4med-target-group-business-woman-03-1-1600x1067.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"4\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/","url":"https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/","name":"Anforderungen an Trockeneis und Fl\u00fcssigstickstoff","isPartOf":{"@id":"https:\/\/www.tec4med.com\/de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/#primaryimage"},"image":{"@id":"https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tec4med.com\/wp-content\/uploads\/tec4med-target-group-business-woman-03-1.jpg","datePublished":"2023-04-28T12:31:08+00:00","dateModified":"2023-04-28T13:11:26+00:00","description":"Minimieren Sie die Sicherheitsrisiken bei der Lagerung oder dem Transport von Kryogenen Stoffen, Chemikalien & Pharmazeutika","breadcrumb":{"@id":"https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/#primaryimage","url":"https:\/\/www.tec4med.com\/wp-content\/uploads\/tec4med-target-group-business-woman-03-1.jpg","contentUrl":"https:\/\/www.tec4med.com\/wp-content\/uploads\/tec4med-target-group-business-woman-03-1.jpg","width":5760,"height":3840,"caption":"Mature woman showing something to male colleague on printing machine. Workers looking at printing press and discussing."},{"@type":"BreadcrumbList","@id":"https:\/\/www.tec4med.com\/de\/anforderungen-an-trockeneis-und-fluessigstickstoff\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tec4med.com\/de\/"},{"@type":"ListItem","position":2,"name":"Anforderungen an Trockeneis und Fl\u00fcssigstickstoff (LN2) f\u00fcr Kryolagerung und -versand"}]},{"@type":"WebSite","@id":"https:\/\/www.tec4med.com\/de\/#website","url":"https:\/\/www.tec4med.com\/de\/","name":"Tec4med Lifescience GmbH","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tec4med.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"}]}},"fields":{"excerpt":"","produkt":false,"featured":false,"hide_from_slider":false,"teaser_icon":false,"hero_content":"","hero_image":false,"animated_image":false,"intro":"","hero_ausblenden":false,"footer_headline":"<p>Kontaktieren Sie um mehr \u00fcber unsere L\u00f6sungen zu erfahren!<\/p>\n","landing_formular":"49","formular_footer_ausblenden":false,"header_button_text":"Kontakt","header_button_link":{"title":"Kontakt","url":"#contact","target":""},"header_button_ausblenden":false},"post_thumbnail":{"large":"https:\/\/www.tec4med.com\/wp-content\/uploads\/tec4med-target-group-business-woman-03-1-1600x1067.jpg","medium":"https:\/\/www.tec4med.com\/wp-content\/uploads\/tec4med-target-group-business-woman-03-1-300x200.jpg","full":"https:\/\/www.tec4med.com\/wp-content\/uploads\/tec4med-target-group-business-woman-03-1.jpg"},"_links":{"self":[{"href":"https:\/\/www.tec4med.com\/de\/wp-json\/wp\/v2\/landingpages\/9590","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tec4med.com\/de\/wp-json\/wp\/v2\/landingpages"}],"about":[{"href":"https:\/\/www.tec4med.com\/de\/wp-json\/wp\/v2\/types\/landingpages"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tec4med.com\/de\/wp-json\/wp\/v2\/media\/3298"}],"wp:attachment":[{"href":"https:\/\/www.tec4med.com\/de\/wp-json\/wp\/v2\/media?parent=9590"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}